🔍 Step 1 – Vacuum Test
- Set the XDC50 to “Vehicle Drain” mode. 
- Block the nylon hose with your finger. 
➡️ Result interpretation:
| Gauge reading | Diagnosis | 
| Vacuum gauge < 0.70 bar | 🔧 Venturi potentially clogged | 
| Vacuum gauge ≥ 0.70 bar | ⚠️ Issue with the hose + rubber cone | 
🧪 Checks to perform
- Nylon hose
 🔄 Hose bent → Replace
- Rubber cone
 ❌ Worn or scratched → Replace
- Elbow connector
 🔄 Leaking or hose no longer secured → Cut 2 cm off the hose and reattach ➤ Otherwise, replace the whole assembly
- Reinforced hose
 🔥 Pierced or burned → Cut off the damaged section and reattach ➤ Otherwise, replace
🧼 Venturi cleaning
⚠️ Warning: Drain the fresh fluid tank before servicing.
Disassembly steps:
- Open the panel on the “Fresh Fluid Valve” side ➤ Use a 6 mm Allen key ➤ Unscrew 3 screws 
- Unclip the 2 hoses and remove the panel 
3. Dismantle the valve + silencer assembly
4. Remove the fresh fluid tank support ➤ 2 mm Allen key ➤ Unscrew 4 screws
5. Unclip the 4 hoses and extract the Venturi
6. Clean and blow out the Venturi port with compressed air
🔄 Reassembly
- Reinstall the Venturi and the dismantled components. 
- Test again in “Vehicle Drain” mode. 
- Block the nylon hose (rubber cone) with your finger. 
- Check that the vacuum gauge exceeds 0.70 bar. 
📞 If not conclusive:
Contact the hotline at +33 4 77 92 13 00 📧 or by email at: reclamation@sam.eu