This begins the session, where the duty table's variable dimension values are captured directly from a real project's Data tree.
Prerequisites
Previous Duty Tables operation steps are completed.
A DigiPara Liftdesigner project open with the elevator configuration you want to capture values from.
Steps
1.) Add a record for a new DTVarGroupTab. In the DTVarTab (grouped) table (L_DTVarGroupTab), add a new record for the group of variable values this duty table needs.
2.) Copy a value from the DigiPara Liftdesigner Data tree. In your open project, open the Data tree, locate the value you want to capture (for example the distance from the counterweight to the center line of the car), right-click it, and choose Copy for Program. The reference is copied without the shaft number — for example Shaft.CW.CL_DIST rather than Shaft0.CW.CL_DIST.
3.) Paste the reference into a new DTVarTab record. In the L_DTVarTab sub-table, add a new record, paste the copied reference into DTV_VARNAME, and fill in its corresponding DTV_VALUE and description.
Result
The duty table now has a group of variable values, captured directly from a real project's Data tree references rather than typed in by hand.