Prerequisites
The fixing element is loaded in Liftdesigner.
Steps
1.) Load the Developer Work Area. Select the fixing element in an existing view frame and click Develop this BIM Component — the component appears in the developer view frames.
2.) Change the profile's size and position. In the profile's Properties window, change the size DY, then define an appropriate formula for the position in Y-direction — Y0 [mm] — which always works out to half of the size DY.
3.) Save the fixing element into the DigiPara BIM Library. Save the finished component. Do this after each processing step on the component's geometry.
Result
The door fixing element's profile has the correct size and position, and the finished component is saved in the DigiPara BIM Library.